Compass Pool Heater – Home Assistant Integration

hacs_badge

A Home Assistant custom integration for Gulfstream, Aqua Comfort, Built Right, and other pool/spa heat pumps that use the ICM Controls Compass WiFi module and the Compass mobile app.

Features

Platform Entities
Climate Full thermostat control — Off / Pool Heat / Spa Heat, target temperature (50-104°F or Off)
Sensors Water Temperature, Coil Temperature, Pool Setpoint, Spa Setpoint, System Mode, Fault Status, Defrost Mode, Last Online
Switches Vacation Hold, Pool Cool, Pool Heat/Cool, Defrost Mode (Air/Reverse Cycle), Panel Lock
Numbers Pool Heat/Cool Deadband (2-8°F), Defrost End Temperature (42-50°F), Sensor Calibration (-10 to +10°F), Spa Timer Hours (0-20), Spa Timer Minutes (0/15/30/45)

Requirements

  • A pool/spa heat pump with the ICM Controls Compass WiFi module
  • An active Compass app account (email + password)
  • The heat pump registered and working in the Compass mobile app

Installation

HACS (Recommended)

  1. Open HACS in Home Assistant
  2. Go to Integrations → three-dot menu → Custom repositories
  3. Add https://github.com/cjam28/compass-pool-heater-ha as an Integration
  4. Click Download
  5. Restart Home Assistant

Manual

Copy the custom_components/compass_pool_heater folder into your Home Assistant config/custom_components/ directory and restart.

Setup

  1. Go to Settings → Devices & Services → Add Integration
  2. Search for Compass Pool Heater
  3. Enter your Compass app email and password
  4. If you have multiple heat pumps, select which one to add
  5. Done — entities appear automatically

Entities Reference

Climate

The main thermostat entity with:

  • HVAC Modes: Off, Heat
  • Presets: Pool, Spa
  • Temperature range: 50-104°F (setpoint of 0 = Off)

Sensors

Sensor Description
Water Temperature Current water temperature (°F) — RMT register
Coil Temperature Heat pump coil temperature (°F) — GEN15 register
Pool Setpoint Current pool target temperature or "Off"
Spa Setpoint Current spa target temperature or "Off"
System Mode Off / Pool Heat / Spa Heat
Fault Status No Fault, No Flow, or fault code
Defrost Mode Air Defrost or Reverse Cycle
Last Online Timestamp of last communication

Switches

Switch App Setting API Field
Vacation Hold Vacation Hold VH
Pool Cool #11 Pool Cool DF1
Pool Heat/Cool #12 Pool Heat/Cool DF2
Defrost Mode (Air Defrost) #17 Defrost Mode DFL (1=Air, 0=Reverse Cycle)
Panel Lock #2 Lock LKO

Number Controls

Control App Setting API Field Range
Pool Heat/Cool Deadband #13 Pool Heat/Cool Deadband DFU 2-8°F
Defrost End Temperature #18 Defrost End AXD 42-50°F
Sensor Calibration Sensor Calibration CAL -10 to +10°F
Spa Timer Hours #15 Spa Timer (hours) DF3 0-20
Spa Timer Minutes #15 Spa Timer (minutes) STOF 0, 15, 30, 45

How It Works

This integration communicates with the ICM Controls cloud API at captouchwifi.com — the same backend used by the Compass mobile app. The heat pump connects to WiFi and maintains a persistent connection to the cloud; commands are relayed through it.

Polling interval: 30 seconds (configurable).

API Field Reference

API Field Compass App Setting Description
MD #1 System Mode 0=Off, 1=Pool Heat, 4=Spa Heat
LKO #2 Lock 0=Unlocked, 1=Locked
CHGF #3 Fault Conditions 0=No Fault, 8=No Flow
GEN15 #4 Coil Temperature Read-only sensor (°F)
RMT Water Temperature Read-only sensor (°F)
DF1 #11 Pool Cool 0=Disabled, 1=Enabled
DF2 #12 Pool Heat/Cool 0=Disabled, 1=Enabled
DFU #13 Pool Heat/Cool Deadband Range 2-8 (°F)
DF3 #15 Spa Timer (hours) Range 0-20
STOF #15 Spa Timer (minutes) 0, 15, 30, 45
DFL #17 Defrost Mode 0=Reverse Cycle, 1=Air Defrost
AXD #18 Defrost End Range 42-50 (°F)
CAL Sensor Calibration Range -10 to +10 (°F)
VH Vacation Hold 0=Off, 1=On
RSV1 Pool Setpoint 0=Off, 50-104 (°F)
RSV2 Spa Setpoint 0=Off, 50-104 (°F)

Compatible Hardware

Any pool/spa heat pump using the ICM Controls Compass WiFi module, including:

  • Gulfstream (confirmed working)
  • Aqua Comfort
  • Built Right
  • Other ICM Controls-based units with the Compass app

Automation Blueprints

Pump Coordination

This blueprint automatically coordinates your pool pump with the heater to prevent "No Flow" faults and handle stale temperature readings (the water temp sensor at the heater reads stagnant pipe water when the pump is off).

Three behaviors:

  1. Auto-Start — turns the pump on when heating is activated
  2. Periodic Check — every N minutes, if the heater wants to heat but the pump is off, starts the pump, waits for a fresh reading, and decides whether to keep it running or shut it back off
  3. Auto-Stop — optionally turns the pump off after a configurable delay when the heater is turned off

The blueprint works with any pump controller — njsPC-HA, Pentair ScreenLogic, Hayward OmniLogic, a simple relay switch, or anything else in Home Assistant. You define exactly what "start pump" and "stop pump" mean for your setup via the action selectors.

Setup

The blueprint is automatically installed when you add the integration. After installing or updating via HACS and restarting Home Assistant, you will see a persistent notification prompting you to configure it.

  1. Go to Settings → Automations & Scenes → Blueprints
  2. Find Compass Pool Heater – Pump Coordination
  3. Click Create Automation
  4. Configure the inputs (see below) for your pump setup
  5. Save and enable the automation
Manual import (alternative)

If you prefer to import manually, go to Blueprints → Import Blueprint and paste:

https://github.com/cjam28/compass-pool-heater-ha/raw/main/blueprints/automation/compass_pool_heater/pump_coordination.yaml

Inputs

Input Description Default
Pool Heater Compass heater climate entity —
Water Temperature Sensor Water temp sensor (from heater) —
Pump State Entity Entity showing pump on/off (binary_sensor, switch, etc.) —
Pump "On" State Value State value meaning the pump is running on
Pump Start Action Action(s) to start the pump —
Pump Stop Action Action(s) to stop the pump —
Check Frequency How often to check temp when pump is off Every 60 min
Pump Warmup Time Seconds to run pump for a fresh temp reading 120
Pump-Off Delay Minutes to keep pump on after heater turns off (0 = disabled) 5

Example: Simple On/Off Switch

Input Value
Pump State Entity switch.pool_pump
Pump "On" State Value on
Pump Start Action Service switch.turn_on on switch.pool_pump
Pump Stop Action Service switch.turn_off on switch.pool_pump

Example: njsPC-HA (Multi-Speed Pump)

Input Value
Pump State Entity binary_sensor.pump_running_state
Pump "On" State Value on
Pump Start Action Service script.turn_on on script.pump_set_speed_exclusive with data target: default
Pump Stop Action Service script.turn_on on script.pump_all_speeds_off

Smart Schedule

An all-in-one blueprint for pump scheduling with optional occupancy-based speed control and heater guest/vacant temperature management. Occupancy sensors are not required — without them the blueprint works as a pure time-based pump schedule. Use it alongside the Pump Coordination blueprint above.

Three usage tiers:

Tier What you configure What you get
Time-only Pump actions + schedule times Pump runs low overnight, default midday, off otherwise
Time + manual occupied/vacant Add the Pool Occupied Mode Toggle Same pump schedule plus a dashboard toggle (ON = Occupied, OFF = Vacant) to switch between occupied and vacant heater temperatures
Full occupancy Add occupancy sensors Automatic occupied/vacant switching based on house presence, and pump max speed when the pool is in use

What it does:

  1. Pump Schedule — runs the pump at low speed overnight and default speed midday (times are configurable)
  2. Heater-Aware Pump Control — at schedule boundaries, if the heater is in heat mode the pump drops to low speed instead of turning off, preventing No Flow faults
  3. Pool Occupancy Override (optional) — when the pool area is occupied, the pump switches to max speed; when guests leave, it returns to the scheduled speed
  4. Heater Occupied/Vacant Mode (optional) — when the house is occupied, the heater is set to the occupied temperature (default 86°F); after no occupancy for a configurable period (default 12 hours), it drops to the vacant temperature (default 78°F)
  5. Dashboard Toggle (optional) — a Pool Occupied Mode input_boolean (ON = Occupied, OFF = Vacant) can be toggled manually from the dashboard to override occupancy detection

Prerequisites

If using occupied/vacant temperature mode (Tier 2 or 3), create one helper:

  • Settings → Devices & Services → Helpers → Create Helper → Toggle
  • Name it Pool Occupied Mode (entity: input_boolean.pool_occupied_mode)
  • ON = Occupied (heater at occupied temperature), OFF = Vacant (heater at vacant temperature)

For time-only mode (Tier 1), no helpers are needed.

Setup

  1. Go to Settings → Automations & Scenes → Blueprints
  2. Find Compass Pool Heater – Smart Schedule
  3. Click Create Automation
  4. Configure the required inputs (Pool Heater, pump actions, schedule times)
  5. Optionally fill in Pool Occupied Mode Toggle, House Occupancy Sensor, and/or Pool Area Occupancy Sensor for additional features
  6. Save and enable
Manual import (alternative)

If you prefer to import manually, go to Blueprints → Import Blueprint and paste:

https://github.com/cjam28/compass-pool-heater-ha/raw/main/blueprints/automation/compass_pool_heater/pool_smart_schedule.yaml

Inputs

Input Required Description Default
Pool Heater Yes Compass heater climate entity —
Pool Occupied Mode Toggle No input_boolean helper (ON = Occupied, OFF = Vacant) (blank)
House Occupancy Sensor No Binary sensor or group for house occupancy (blank)
Pool Area Occupancy Sensor No Binary sensor or group for pool area (blank)
Pump Low Speed Action Yes Action(s) to set pump to low speed —
Pump Default Speed Action Yes Action(s) to set pump to default speed —
Pump Max Speed Action No Action(s) to set pump to max speed (only with pool occupancy) (none)
Pump Off Action Yes Action(s) to turn pump off —
Occupied Temperature — Heater setpoint when toggle is ON (occupied) 86°F
Vacant Temperature — Heater setpoint when toggle is OFF (vacant) 78°F
Vacant Mode Delay — Hours of no occupancy before switching to vacant temp 12
House Occupied Debounce — Seconds house sensor must stay on before toggling to occupied 30s
Pool Occupied Debounce — Seconds pool sensor must stay on before switching to max speed 30s
Pool Cooldown — Minutes after pool area clears before dropping from max speed 5
Night Pump Start — Overnight low-speed filtration start time 10:00 PM
Night Pump End — Overnight filtration end time 6:00 AM
Midday Pump Start — Midday circulation start time 11:00 AM
Midday Pump End — Midday circulation end time 2:00 PM

Example: Time-Only (Single-Speed Pump, No Occupancy)

Input Value
Pool Heater climate.bali
Pump Low Speed Action Service switch.turn_on on switch.pool_pump
Pump Default Speed Action Service switch.turn_on on switch.pool_pump
Pump Off Action Service switch.turn_off on switch.pool_pump

Leave Pool Occupied Mode Toggle, House Occupancy Sensor, Pool Area Occupancy Sensor, and Pump Max Speed Action blank.

Example: njsPC-HA (Multi-Speed Pump with Occupancy)

Input Value
Pool Occupied Mode Toggle input_boolean.pool_occupied_mode
House Occupancy Sensor binary_sensor.house_occupancy
Pool Area Occupancy Sensor binary_sensor.pool_area_motion
Pump Low Speed Action script.pump_set_speed_exclusive with data target: low
Pump Default Speed Action script.pump_set_speed_exclusive with data target: default
Pump Max Speed Action script.pump_set_speed_exclusive with data target: max
Pump Off Action script.pump_all_speeds_off

Using Both Blueprints Together

The Pump Coordination and Smart Schedule blueprints are designed to work together. Smart Schedule manages the pump timetable and heater setpoints; Pump Coordination acts as a safety net to ensure the pump runs whenever the heater needs water flow.

Recommended Pump Coordination settings when using Smart Schedule:

Setting Recommended Value Why
Pump-Off Delay 0 (disabled) Smart Schedule already manages pump on/off timing. A non-zero delay would turn the pump off mid-schedule window when the heater turns off.
Check Frequency Every 15 minutes Shorter interval means Pump Coordination catches any gaps faster.

How they interact: Smart Schedule controls the pump schedule, but if the heater is in heat mode it keeps the pump at low speed instead of turning it off at schedule boundaries. Pump Coordination's periodic check catches any remaining case where the pump is off but the heater needs flow, starts the pump, checks the temperature, and either keeps it running or shuts it back off.

Troubleshooting

  • "Invalid email or password": The API uses your email as the username field. Make sure you can log in to the Compass mobile app with the same credentials.
  • Stale data: The cloud API is polled every 30 seconds. If the heater is offline, the last known state is shown.
  • "No Flow" fault: This is reported by the heat pump itself when it detects insufficient water flow. Check your pool pump.

Known Fault Codes (CHGF register)

Extracted from the Compass app source:

CHGF Value Fault Description
0 No Current Fault
8 No Flow (confirmed)
? Evap. Sensor Malfunction
? Water Sensor Malfunction
? Low Pressure Switch
? High Pressure Switch

Only CHGF=8 has been confirmed via live testing. The other fault codes exist in the app but their exact CHGF values haven't been mapped yet. If you encounter a different fault code, the raw value will be shown — please report it so we can complete the mapping!

License

MIT

About

Home Assistant integration for **Gulfstream**, **Aqua Comfort**, **Built Right**, and other pool heat pumps controlled by the **Compass WiFi** app (by ICM Controls).