SCD4x ambient pressure compensation unit confusion #19751

Description

@j9brown

The problem

The SCD4x component's ambient_pressure_compensation value is defined and documented with different units of pressure.

  • The documentation states that the units are mbar.
  • The Python config validation uses cv.pressure whose default units are bar.
  • The C++ implementation does not perform any scaling on the received value so it assumes they are in mbar as specified in the scd4x datasheet.

Unlike SCD30's unit confusion (esphome/esphome.io#7449), this confusion is not just a documentation error. If the SCD4x configuration specifies a value with units then the metric prefix scaling will apply during validation and an unexpected value will be provided to the component during initialization.

  • Given ambient_pressure_compensation: 1013
    • Docs imply this is 1013 mbar
    • Python config validation defaults units are bar so technically this is 1013 bar, oops
    • C++ implementation receives the value 1013 and wants mbar, ok
    • The mistakes cancel out so everything works out at runtime
  • Given ambient_pressure_compensation: 1013 mbar
    • Python config validation sees m prefix on bar so divides by 1000 to get 1.013 bar
    • C++ implementation receives the value 1.013 and wants mbar, oops
    • The wrong value will be applied at runtime

Fixing this unit confusion may require a breaking change. Perhaps something like:

  • Change the docs to indicate that the units are in bar (part of the same fix as for SCD30).
  • Add a cv.float_range(0.4, 1.1) check to catch the case where a large unitless value that was assumed to be mbar was provided. The fix for this breakage is to simply add the mbar unit to the configuration.
  • Change to_code to multiply the configured value by 1000 to yield a pressure in mbar (aka. hpa) as required by the C++ code.

Which version of ESPHome has the issue?

2026.10.0-dev

What type of installation are you using?

Home Assistant Add-on

What platform are you using?

ESP8266

Component causing the issue

scd4x

YAML Config

sensor:
  platform: scd4x
  ambient_pressure_compensation: 1013 mbar  # actually interpreted as 1.013 bar
  # etc...

Anything in the logs that might be useful for us?

Additional information

No response

Activity

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions