The problem
The SCD4x component's ambient_pressure_compensation value is defined and documented with different units of pressure.
- The documentation states that the units are mbar.
- The Python config validation uses
cv.pressure whose default units are bar.
- The C++ implementation does not perform any scaling on the received value so it assumes they are in mbar as specified in the scd4x datasheet.
Unlike SCD30's unit confusion (esphome/esphome.io#7449), this confusion is not just a documentation error. If the SCD4x configuration specifies a value with units then the metric prefix scaling will apply during validation and an unexpected value will be provided to the component during initialization.
- Given
ambient_pressure_compensation: 1013
- Docs imply this is 1013 mbar
- Python config validation defaults units are bar so technically this is 1013 bar, oops
- C++ implementation receives the value 1013 and wants mbar, ok
- The mistakes cancel out so everything works out at runtime
- Given
ambient_pressure_compensation: 1013 mbar
- Python config validation sees
m prefix on bar so divides by 1000 to get 1.013 bar
- C++ implementation receives the value 1.013 and wants mbar, oops
- The wrong value will be applied at runtime
Fixing this unit confusion may require a breaking change. Perhaps something like:
- Change the docs to indicate that the units are in bar (part of the same fix as for SCD30).
- Add a
cv.float_range(0.4, 1.1) check to catch the case where a large unitless value that was assumed to be mbar was provided. The fix for this breakage is to simply add the mbar unit to the configuration.
- Change
to_code to multiply the configured value by 1000 to yield a pressure in mbar (aka. hpa) as required by the C++ code.
Which version of ESPHome has the issue?
2026.10.0-dev
What type of installation are you using?
Home Assistant Add-on
What platform are you using?
ESP8266
Component causing the issue
scd4x
YAML Config
sensor:
platform: scd4x
ambient_pressure_compensation: 1013 mbar # actually interpreted as 1.013 bar
# etc...
Anything in the logs that might be useful for us?
Additional information
No response
The problem
The SCD4x component's
ambient_pressure_compensationvalue is defined and documented with different units of pressure.cv.pressurewhose default units are bar.Unlike SCD30's unit confusion (esphome/esphome.io#7449), this confusion is not just a documentation error. If the SCD4x configuration specifies a value with units then the metric prefix scaling will apply during validation and an unexpected value will be provided to the component during initialization.
ambient_pressure_compensation: 1013ambient_pressure_compensation: 1013 mbarmprefix onbarso divides by 1000 to get 1.013 barFixing this unit confusion may require a breaking change. Perhaps something like:
cv.float_range(0.4, 1.1)check to catch the case where a large unitless value that was assumed to be mbar was provided. The fix for this breakage is to simply add thembarunit to the configuration.to_codeto multiply the configured value by 1000 to yield a pressure in mbar (aka. hpa) as required by the C++ code.Which version of ESPHome has the issue?