@@ -56,7 +56,7 @@ US 021: Accepted, fixed in 50e55ce9.
5656 * Split index entries to "block (execution)" and "block (statement)".
5757 * Also added the statement form to Clause 3, Terms and Definitions.
5858
59- GB 022: Accepted, fixed in 8cc6bd34.
59+ GB 022: Accepted with modifications , fixed in 8cc6bd34.
6060
6161 * The relevant change had already been made to [ using.headers] ,
6262 but this corresponding change was missed.
@@ -137,7 +137,7 @@ US 155: Propose accepting; **LWG to approve direction**
137137JP 177: Accepted, fixed in 8be40ff0.
138138
139139 * Replaces a reference to ISO/IEC/IEEE 60599 with a reference to the intended ISO/IEC/IEEE 60559.
140- * IEC 60599 is "Mineral oil filled electrical equipment in service --
140+ * IEC 60599 is "Mineral oil- filled electrical equipment in service --
141141 guidance on the interpretation of dissolved and free gases analysis"
142142 * ISO/IEC/IEEE 60559 is "Information Technology - Microprocessor Systems --
143143 Floating-Point Arithmetic"
@@ -191,12 +191,12 @@ US 325: No consensus for change.
191191 but will reconsider the organization of the standard library clauses
192192 for a future standard.
193193
194- US 327: ** SG8 / LEWG to handle issue**
194+ US 327: ** SG6 / LEWG to handle issue**
195195
196196 * The proposed change is not editorial.
197197 * Duplicate of PL 326
198198
199- US 328: ** SG8 / LEWG to handle issue**
199+ US 328: ** SG6 / LEWG to handle issue**
200200
201201 * The proposed change is not editorial.
202202
0 commit comments